We offer our clients with a wide range of automatic control panels that is designed at par with the specific requirements of our clients. These automatic control panels are compact in design and precision engineered panels are widely used for instant switch over in various industrial applications. Available at highly competitive prices, these automatic control panels are widely demanded in the market.

Our range of automatic control panels includes electric control panels, industrial automation panels, line interactive voltage control panels,
sub-immersible control panels, soft start sequence control panels, neutral failure circuit breakers, ryb phase sequence corrector and automatic phase changers.



Electric Control Panels
Enlarge View

Electric Control Panels

We are instrumental in offering Electric Control Panels that are designed and developed using micro controller and embedded technology. Manufactured using superior quality and well tested switches, fuses and controllers, these Electric Control Panels are widely appreciated by our clients for optimum performance and durability. Further, to impart proper finish and prevent these from corrosion, these automatic control panels are properly powder coated and are hence extensively used in Engineering, Automobile and Electrical industry.

Our electric control panels are used in the following areas:

  • Process control systems
  • Drying systems control
  • Transfer pump control
  • Lift stations
  • Environmental remediation systems
  • Waste water treatment systems
  • pH controllers
  • Well pump and water tower control
  • Groundwater treatment systems
  • Chemical feed pump systems
  • Gas collection sump dewatering
  • Pneumatic pump controllers
  • Vapor extraction controls
  • Odor control systems

Request for Quotation

Industrial Automation Panel

In industries different types of machinery and equipment may have come. But for all this things we require electricity power supply panels with automation controls, auto power management and safety structures timing along with other features. We make Industrial Automation Panels as per customer requirement and compactable.

Request for Quotation

Industrial Automation Panel
Enlarge View

Soft-Start Sequence Control Panel
Enlarge View

Soft-Start Sequence Control Panel

To start the motor slowly and to avoid large current consumption during starting time of the motor, we provide soft start sequence control panel.

Features:

  • Avoid voltage Trip
  • Saves Energy
  • Avoid Electricity boards Penalty
  • Controls the maximum demand power

Request for Quotation

Neutral Failure Circuit Breaker

The Neutral Failure Circuit Breaker offer by us protects our single phase equipment and wirings from high voltage, neutral failure and phase to phase current. Based on micro process controller technology, Neutral Failure Circuit Breaker helps in avoiding damages due to electrical fire.

The Neutral Circuit Breaker offer by us protects our single phase equipment and wirings from high voltage, neutral failure and phase to phase current. Based on Micro Process Controller Technology, it helps in avoiding damages due to electrical fire and high voltages. Even if high voltage occurs, in any phase line, the load will be tripped off. It finds application in Police Head-Quarters, big buildings and many more.

Application:

Used at Flats, Residence, Offices, Buildings & Factories. This protects a Single Phase Equipment and Wirings from Neutral Failure, High Voltage, Phase to Phase Current, 440V, etc.

Models & Amps/ Kva Rates:

30 Amps, 40A, 60A, 80A, 100A, 150A, 200A, 250A, 300A, 350A, 400A, 450A, upto 630 Amps.

Features:

  • World advanced Micro Process Controller Technology is used
  • Automatically cut off the Main A/c, when sudden high voltage, 440V, Phase-to-Phase or phase –in- Neutral
  • High Voltage Cut off at 295V(L&N) is also available
  • Avoids fire and damages to the Single Phase electrical appliances and wiring
  • Current Sensing devices like ELCB, MCB and Fuse Carriers will NOT trip off during the Neutral failure
  • Certified by ETDC (Electronic Test & Development Center) GOVT. of India What happens when the Neutral is Failed
  • If Neutral fails, phase will return to the Neutral wire and due to this, phase will pass through the entire Neutral wirings, which gets high voltage (ie) above 380V. So that all the Single Phase Appliance will receive Phase 1 & Phase 2 instead of Phase & Neutral. i.e., 220V 220V = 440V. i.e., Phase to Phase
  • When Neutral fails at the balance or unbalanced load condition, using Micro Controller Technology, our NFCB will sense the return phase and it will trip the Power to the load
  • Even if high voltage occurs, in any phase line, load will be tripped off

Clients:

  • Tamil Nadu Police Quarters - Head Office
  • Prahari Builders
  • Swathi Aqua
  • Air Fridge
  • Nalsa Medical Industries and many more

Request for Quotation

Neutral Failure Circuit Breaker
Enlarge View

Automatic Phase Changer
Enlarge View

Automatic Phase Changer

Our range of Automatic Phase Changers is widely appreciated by our clients for superior quality and optimum performance. The automatic phase changers & changeover offered by us automatically makes use of available phase lines, during the phase failure. It also cuts-off low voltage line in milliseconds and changes it to the next line. It is mainly installed at residences and small offices, where single phase equipment is used. These are available in two models i.e. auto switch-off and phase changer with distribution board.

Our automatic phase changers are reckoned for the following distinguishing features:

  • Automatically changes the available phase lines to the non-available phase lines
  • Certified by CETL- Govt. of Tamilnadu
  • Restore to the actual lines when the failure lines are restored
  • Cut off at low voltage and changes to the next lines; changes in milliseconds
  • Phase changer cum changeover model with auto switch off the generator (VTSL
  • Model)
  • Phase changer with distribution board models also available
  • Models & Amps/ KVA Rates: 30 Amps, 40A, 60A, 120A, 180A, 300Amps.

Our automatic phase changers are used by the following:

  • Building promoters
  • Builders
  • Electrical contractors
  • Residential spaces

Request for Quotation



Contact us

Mr. S. Prem Kumar (Proprietor)
305/2, 2nd Floor, Triplicane High Road, Triplicane
Chennai, Tamil Nadu - 600 005, India
Telephone:  +(91)-(44)-28587947/ 28591553/ 28583806

Contact via E-mail

Contact via Mobile

Contact via SMS

Home | About Us | Products | Media Gallery | Site Map | Contact Us | Enquiry

Member IndiaMART.com © Volt-On Engineering. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


Add More Products / Services

(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code:

Send me a copy of this enquiry